About the battery pack online equalization charging problem

- Aug 30, 2019-

The voltage deviation of the valve-regulated sealed battery terminal is divided into: 1. The open circuit voltage deviation, that is, the voltage deviation of the battery in a static state, should not exceed 20mv; 2. The dynamic deviation, that is, the battery is in the charging operation state, should not exceed 50mv. Detailed can check "communication industry standards - YD/T799-1996